How does the compost turner machine daily maintain?
1、When the compost turner machine does not work regularly, it will be maintained once a week. When you do your homework, you need to maintain it every day
2、Check whether the fasteners are strong, and whether the bearing clearance of the transmission parts is appropriate (too loose, too tight to be a phenomenon of transmission resistance), and the gap should be adjusted in time.
3、Check whether the knife is defective and the fastening bolt is loose, and when necessary, tighten or replace the new blade.
4、Check the diesel engine, gearbox, axle bearing and other parts to be loose.
Maintenance after shutdown:
◆ clean residues from frame and crawler of HINDA compost turning machine after shutdown;
◆ lubricate each lubricating point in time.
◆ cut off power.
Hydraulic System Maintenance
In order to ensure hydraulic equipment can meet the high production capacity, and stable and reliable technological performance, requirements for the hydraulic system must be skilled operation, reasonable adjustment, careful maintenance, and planned maintenance. Requirements are as follows:
● Reasonable adjust working press and speed of hydraulic system according to requirements of introduction and working requirement. when the pressure value and the speed control value are at the desired value, it should adjust the screw fixation to prevent loosening.
● select suitable hydraulic oil according to instructions and provisions of the brand; change unqualified oil immediately once found.; filter oil before refueling; At the same time, remember regularly check the oil to ensure the best oil quality.
● The working temperature of oil needs to be below 80 degrees, with general control in the range of 35-70 degrees. Check for the reason when the temperature is more than the specified range.
● Ensure stable voltage; keep fluctuation value not exceed the rated voltage of +5%-15%.
● Forbid working and adjusting press under the situation of defective pressure gauge or no-press gauge.
● Close electrical cabinets, electrical box, operating platform and command control box lid when not used.
● When a part of a hydraulic system fails (such as hydraulic instability, low oil press and vibration), it is necessary to analyze all causes and repair in time where forced running may cause major accidents.
● Periodic check cooler and heater.
● Regularly observe the working performance of the accumulator, if the air pressure is insufficient or oil or gas is mixed, it should timely inflate and repair it.
● Regularly replace seal parts every one and a half years.
● Regularly measure and replace the performance of the main components.